Next: Intermediate Experiment 1
Up: The Details of the
Previous: Parameter Estimation and Model
  Contents
The convergence of the estimates of some of the various parameters, in
the main and null models, is displayed in figures
5.11,
5.12, and 5.13.
Figure 5.11:
The Convergence of the Electrostatic Potential with No Film,
Displayed as a Graph of the Iteration Mean and Root Mean Square of
the Potential, for Each Model, Against Iteration Number
 |
Figure 5.12:
The Convergence of the Electrostatic Potential with Film
Thickness 5, Displayed as a Graph of the Iteration Mean and Root
Mean Square of the Potential, for Each Model, Against Iteration
Number
 |
Figure 5.13:
The Convergence of the Magnetic Flux Density with Film
Thickness 5, Displayed as a Graph of the Iteration Mean and Root
Mean Square of the Flux Density, for the Main Model, Against Iteration
Number
 |
Having presented and discussed the results of the main experiments, it
is now time to present results of some similar, earlier experiments;
the primary use of these experiments will not be in inferring physical
properties of samples, but in identifying imperfections in the
experimental methods, the solutions to which motivate, and are built
into, the experimental methods above.
Next: Intermediate Experiment 1
Up: The Details of the
Previous: Parameter Estimation and Model
  Contents
Daniel Christopher Hatton
2004-11-30